SVS (Three Phase Air Cooled)

Salient Features

  • Microcontroller based with digital display and advanced sensing
  • Single Phase Prevention & Phase Reversal Trip
  • Short Circuit, Overload, Overvoltage/Undervoltage Trip
  • Panel indication & alarm before trip
IndustrialResidentialCommercial ComplexesLight ManufacturingPackaging LinesRetail MallsTextile Mills

SVS (Three Phase Air Cooled)

Technical SpecificationsISO 9001:2015
Rating
3KVA - 150KVA
Input Voltage Range
340V-480V, 340V-520V, 295V-480V, 270V-480V, 240V-480V AC
Output Voltage
415V / 400V / 380V ±1%
Type
Three phase, Unbalanced type
Correction Rate
70 V/s
Response Time
10 mili sec
Winding
Copper wire H class / Aluminium wire H class(on Order)
Cooling Mechanism
Natural Air Cooled / Forced Air Cooled
Cabinet
CRC Steel Sheetmetal powder coated with rolling wheels
Engineering FAQ Background
Technical Knowledge Base

Engineering FAQ

Air-cooled units (typically up to 60 KVA) are compact, require less maintenance, and are ideal for clean indoor environments like IT server rooms. Oil-cooled units (up to 600 KVA+) are designed for harsh, dusty industrial environments like steel mills and heavy fabrication, as the oil provides superior thermal dissipation for continuous heavy-duty cycles.
Yes. Our unbalanced-type 3-Phase Servo Voltage Stabilizers feature three independent servo motors and control circuits. This ensures that even if one phase experiences a severe voltage drop (e.g., from a heavy motor startup), the other two phases remain perfectly regulated at 240V (Phase-to-Neutral).
Our standard SVS architectures feature a correction rate of up to 35 Volts per second, ensuring that sudden grid fluctuations are mitigated before they can trip sensitive PLC controls or VFDs.